Welcome to Hvacproforums, an interactive community exclusively for HVAC professionals. The collective years of HVAC experience and the knowledge our forum members share make this an invaluable resource for those in the HVAC industry. We have a lot of fun, but make no mistake, we are pros. Hvacproforums is self supporting.there are NO advertisers here. Do-it-yourselfers and Homeowners are encouraged to seek information elsewhere. Those involved in the HVAC industry are urged to register. Its 100% free and easy, Once registered you will have access to the technical forums, Be sure to click over to the new members forum and introduce yourself after registering!

This one doesn't have the display with all the codes for lockouts, just says a fault occurred and it needs to be reset. I checked the oil level already. I will check the pressure differential when I go back. It has the helical compressors with the built in oil filters. Manual says that they don't need to be replaced so maybe a faulty oil pressure switch? It's a single inlet, non-adjustable switch mounted in the terminal cover with a pigtailed cap tube going to the oil pressure tap or nearby there.I think. This one doesn't have the display with all the codes for lockouts, just says a fault occurred and it needs to be reset.

I checked the oil level already. I will check the pressure differential when I go back. It has the helical compressors with the built in oil filters. Manual says that they don't need to be replaced so maybe a faulty oil pressure switch? It's a single inlet, non-adjustable switch mounted in the terminal cover with a pigtailed cap tube going to the oil pressure tap or nearby there.I think. Click to expand.When it says 'fault has occured' press the next or plus button to get to the actual fault description.

Rtaa

Im pretty sure only the RTAA 130ton and larger have an actual oil pressure diff switch, smaller chillers dont. They use the chillers temperature sensors and control logic for oil faults. Oil filters may need to be replaced, need to read the manual and check pressure drop. I find that mostly the chillers with remote condensers and/or coolers are the ones that have oil filter issues. How old is this machine?

. North America. United States ( ). Canada ( ). Latin America.

Argentina ( ). Mexico ( ).

Brazil ( ). Aruba ( ).

Bahamas ( ). Belize ( ). Bermuda ( ).

Bolivia ( ). Bonaire ( ). Cayman Islands ( ). Chile ( ). Colombia ( ). Costa Rica ( ). Curacao ( ).

Dominican Republic ( ). Ecuador ( ). El Salvador ( ).

Grenada ( ). Guadeloupe ( ). Guatemala ( ).

Guyana ( ). Haiti ( ). Jamaica ( ).

Martinique ( ). Netherland Antilles ( ).

Nicaragua ( ). Panama ( ). Paraguay ( ). Peru ( ). Puerto Rico ( ). Saint Lucia ( ). St.