Fx 3s Series Programmable Controller Manual

Posted on
  1. Fx 3s Series Programmable Controllers Manual

Melsec-f fx series programmable controllers data communication edition (818 pages) Controller Mitsubishi Electric FX3U-128ASL-M User Manual Melsec-f fx3u (90 pages).

FX3S CPU Base Units The FX3S is the fit-and-forget PLC solution for space and cost conscious applications requiring up to 30 I/O. This minimum-expandability, battery-less maintenance free controller is perfect for handling straightforward processes and can be hidden away in locations without regular maintenance activities. 3rd Generation Basic Compact PLC High performance with minimal size Integrated power supply (AC powered) Maintenance-free EEPROM memory Ample memory capacity (4000 steps) and device ranges Built-in USB port for the programming communication function to enable high-speed communication at 12Mbps Built-in positioning control Integrated real-time clock Increased functionality using Expansion Boards and Special Adapters Programming with GX Works2 or GX Works2 FX.

For Use With FX3 Series Number of I/O 20 Manufacturer Series FX3S Number of Inputs 12 Input Type DC Voltage Category 100 → 240 V ac Output Type Relay, Transistor Number of Outputs 8 Network Type Ethernet, ModBus Communication Port Type RS422, USB Program Capacity 4000 Steps Maximum Inputs/Outputs 20 Number of Communication Ports 2 Depth 90mm Minimum Operating Temperature 0°C Dimensions 75 x 75 x 90 mm Programming Language Used Instruction List, SFC, Step Ladder Maximum Operating Temperature +55°C Width 75mm Mounting Type Wall Mount Length 75mm Memory 4000 Steps Output Current 2 A. The product detailed below complies with the specifications published by RS Components. Where applicable it provides assurance that electrostatic discharge sensitive devices have been handled and packed under conditions that meet the administrative and technical requirements of the ANSI/ESD S and BS EN 61340-5-1:2007 Electrostatic Control Standards. 795-7978 Description Mitsubishi FX3S PLC CPU, Ethernet, ModBus Networking, 4000 Steps Program Capacity, 12 Inputs, 8 Outputs Manufacturer/Brand: Mitsubishi Mfr.

. For the control panel, use the product having sufficient strength, fire Please consult with Mitsubishi Electric for information on UL, cUL standard practices. The PLC is a precision instrument.

During transportation, avoid impacts larger protectiveness and shielding property to an installation environment. 10BASE-T/100BASE-TX connector (RJ45) these users should follow those manufacturers' installation requirements. 40 point I/O type cannot use the BD1 slot. Mitsubishi Electric recommends that shielded cables be used. If NO other EMC - FX -CNV-ADP, FX -ENET-ADP cannot be connected. 3.2 Installation location Built-in Ethernet part.2 Dielectric withstand voltage and insulation resistance are shown in the following INSTALLATION table.

PRECAUTIONS Install the PLC in an environment conforming to the generic specifications (section Status Description display color Insulation 3.1), installation precautions and notes. 3.3 Procedures for installing to and detaching from DIN rail 4.2 Power supply specifications and example of external Notes 4. Power supply/input/output specifications and external wiring The products can be installed on a DIN46277 rail 35mm (1.38”) wide. Wiring example of the main unit part. JY997D49401H 4.2.3 Example of external wiring (DC power type) 4.4 Input specifications and external wiring 4.4.3 Examples of input wiring DC power type 4.5 Relay output specifications and example of external wiring 24V DC power is supplied to the main unit and input/output extension unit. As for the details of the input specifications of I/O extension unit/block and external 1.Sink input type 2.Source input type. Do not disassemble or modify this product.

Controllers

Fx 3s Series Programmable Controllers Manual

Controller

Doing so may cause fire, equipment failures, or malfunctions. For repair, contact your local Mitsubishi Electric representative. The adapter case is made of resin. If dropped or subjected to strong impact, the adapter may be damaged. 3) Termination Failure to do so may cause fire, equipment failures or malfunctions.

For repair, contact your local Mitsubishi Electric representative. Strip the coating of strand wire and twist the cable core before connecting it,. Make sure to observe the following precautions in order to prevent any + side of receiving data. Analog Control Edition. The grounding resistance should be 100Ω or less. Nor does it confer any patent licenses.

Mitsubishi Electric Corporation cannot be resistance is 2kΩ. Resistance is 250Ω. Held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

For the control panel, use the product having sufficient strength, fire Please consult with Mitsubishi Electric for information on UL, cUL standard practices. The PLC is a precision instrument.

During transportation, avoid impacts larger protectiveness and shielding property to an installation environment. Built-in Ethernet part.2 Dielectric withstand voltage and insulation resistance are shown in the following 3.2 Installation location INSTALLATION table. PRECAUTIONS Install the PLC in an environment conforming to the generic specifications (section Status Description display color Insulation 3.1), installation precautions and notes. Do not disassemble or modify this product. Doing so may cause fire, equipment failures, or malfunctions. For repair, contact your local Mitsubishi Electric representative.

The adapter case is made of resin. If dropped or subjected to strong impact, the adapter may be damaged. Analog Control Edition.

The grounding resistance should be 100Ω or less. Nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be resistance is 2kΩ. Resistance is 250Ω.

Held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.